In recent years, an interesting and unique application for laminated glass has emerged. Relying on the strength of laminated glass, designers have begun incorporating structural glass as sides and even bottoms in swimming pools. In response to this trend, members of ASTM’s glass strength committee published a new standard: ASTM E3401 Standard Practice for Design and Performance of Laminated Glass Subject to Hydrostatic Loads. This standard provides guidance for calculating the glass strength and for physical testing under hydrostatic loads. Though primarily for swimming pools and aquariums, this standard may provide some benefit for the design of glass flood barriers as well. This paper will review the new ASTM E3401 standard, including examples of calculations, and explore the unique applications of laminated glass under hydrostatic loads.

 

ang 05 08 Materials technologies GPD basen 1

 

1. Introduction

 

An interesting trend in swimming pool design has emerged over the last several years. Customers and designers want the visual effect of water with no boundaries. Embracing nature’s canvas, the water edge vanishes into the natural landscape.

 

Whether looking at an ocean or mountain view, the pool is transformed into an extension of the surrounding environment. This view is not just from outside the pool, but also from under the water. Incorporating laminated structural glass in pool walls and even floors provide the ultimate feeling of water with no boundaries.

 

Utilizing glass in swimming pools is not a new application as many competition swimming pools have a viewing window installed for recording and analyzing swimmers’ technique; however, this new trend expands on the use of glass and in some cases creating an all-glass pool. While this is an exciting, novel application of laminated structural glass, the questions were raised of how should the glass be designed and are there any applicable standards?

 

To answer these questions, members of ASTM E06.52 Glass Use in Buildings subcommittee began drafting a standard, and the first edition of ASTM E3401/E3401M Standard Practice for Design and Performance of Laminated Glass Subject to Hydrostatic Loads was published in August 2024.

 

This paper will review the new standard and provide some example calculations as well as explore the unique application of laminated glass subject to hydrostatic loads.

 

ang 05 08 Materials technologies GPD basen 2

 

2. Review of ASTM E3401/E3401M – 24

 

2.1. Load Conditions

 

Before performing any calculations, the load conditions must be defined. In the case of swimming pools, the primary load is the pressure exerted by the water onto the glass, or Hydrostatic, which is defined as “of or relating to fluids at rest or to the pressures they exert or transmit” (Merriam-Webster, 2025). The hydrostatic load may be determined by multiplying the height of the water by its density and gravity as shown in equation 1 below where p is pressure (Pa), h is height (m), is density of the fluid (kg/m3), and g is the gravitational constant (9.81 m/s2).

 

p = hρg (1)

 

Based on this equation, the pressure exerted on an object is directly proportional to the depth at which that object is submerged under the water. Following this rule, laminated glass installed vertically as a pool wall will experience greater force at the bottom than at the top. This gradual increasing of pressure is depicted in figure 1. In contrast, laminated glass installed horizontally as a pool floor will experience uniform loading in addition to weight of the glass.

 

In addition to hydrostatic loads, applications designed for human or animal occupation may experience live loads. For instance, a laminated glass pool wall may be subjected to additional stress from a person leaning on or over the edge of the glass. Similar to a glass balustrade application, when the pool is intended for human or animal occupancy, vertical glass shall also have an additional concentrated live load of 0.89 kN applied horizontally to the glass surface spread over an area of 152 mm by 152 mm. Likewise, horizontally installed laminated glass in swimming pools intended for human or animal occupancy may experience live loads similar to glass floors or walkways. In this situation, if the water depth is less than 0.49m, a minimum hydrostatic load of 4.79 kPa shall be used in addition to a concentrated live load of 1.33 kN, or more depending on occupant load, over an area of 152mm by 152mm. In both applications, the live load is applied in conjunction with the hydrostatic load and placed in the location that will maximize the stress and deflection.

 

ang 05 08 Materials technologies GPD basen autor

 

Zapraszamy do zapoznania się z pełną treścią artykułu, który opublikowany został w wydaniu miesięcznika "Świat Szkła"