Energy-efficient refurbishment of protected historic windows and facades
Historic windows in heritage buildings are generally made of timber, steel sections or cast iron and fitted with single glazing. When they are replaced or refurbished, both building-technology requirements and heritage conservation considerations must be taken into account. The external appearance and the construction details are important. Relevant features include the window dimensions and division, including glazing bars, the width of the window frames, the design of the window reveal, the materials and the construction. Because an exact reconstruction means labour-intensive craftsmanship, standard sections are often used in an attempt to replicate the original appearance. Planners and manufacturers are still required to verify the thermal performance values. This article presents design solutions that reconcile thermal insulation with heritage conservation.

Energy performance optimisation
Single-glazed windows are common in heritage buildings, but they are not suitable for operating in an energy efficient building. This creates a considerable conflict of interest between the aims of heritage conservation and users’ expectations regarding modern energy efficiency, safety and comfort. Energy performance can be improved by converting the window into a box-type or coupled window through the addition of a second window plane, adding a secondary or a storm window, installing new glazing, or replacing the window entirely. The window reveal and the connection to the building structure must also be improved to reduce thermal bridges. For any work on the window, the load-bearing capacity and dimensions of the sash, together with the load capacity of the fittings, are often the decisive factors. As a general rule, the new window, sash and glazing must be sealed airtight on the room side, while the cavity must be provided with limited ventilation to the outside.
a) Conversion into a box-type window
Thermal insulation can be improved to Passive House level. Ug/UW value approx. 0.5/0.7 W/(m²K). Sound insulation of up to 40 dB is possible.
b) Conversion into a coupled window
With lightweight double glazing, UW values of up to 1.2 W/(m²K) can be achieved; with VIG, values of 0.5-0.7 W/(m²K) are possible. Sound reduction values of 40-45 dB can be achieved, and sound insulation can be improved by 32 dB.
c) Replacement of the glazing
Replacement with toughened thin glass (3 mm, with a maximum glazing thickness of 14 mm) is possible where a glass edge cover of 15 mm can be achieved. Vacuum glazing with a thickness of approx. 4-6 mm is well suited to replacement applications. U-values*1 for coated single glazing - Ug/UW value approx. 3.0/3.0; thin insulating glass - Ug/UW value approx. 1.1/1.2; and vacuum glazing: Ug/UW value approx. 0.5/0.8 W/(m²K). Design measures, for example regarding the glass edge cover, must be taken into account. A like-for-like replacement of single glazing with VIG is not advisable.
*1) based on the standard window size of 1.23 m x 1.48 m
d) Replacement of the window
Special window sections are available for replacing windows in listed buildings without altering their appearance. Where a UV-resistant edge seal is used, the glazing rebate can be limited to 15 mm. This allows windows designed for protected historic buildings to achieve Passive House performance with a UW value of 0.7 W/(m²K).

Use of vacuum insulating glazing
In cases a.) to c.), thermal insulation can be improved by using vacuum insulating glazing (VIG). Until now, however, there have been no suppliers on the market able to offer products tailored to the wide variety of window sizes and types. In the ‘MOTIVE’ research project, Holzforschung Austria investigated the basic aspects of vacuum-glazed window units and examined the advantages and disadvantages of different design variants, the durability of VIG as a product however was not investigated. All the designs share a very deep glass edge cover of 30-40 mm, which is necessary to compensate for the thermal bridge at the glass edge seal.
Vacuum glazing makes it possible to create slender constructions with good overall energy efficiency, meeting nearly zero-energy building standards, while retaining the section dimensions of old single-glazed timber windows. Its lower weight and reduced glass thickness compared with triple insulating glass also open up opportunities for new opening methods and directions of movement. Further collaborative research is needed to develop suitable sections, locking mechanisms, fittings and gaskets, as well as motorisation and control technology.

Building regulations and durability of vacuum insulating glazing
The European rules for assessing the durability of insulating glass units (IGUs) in the EN 1279 series explicitly exclude vacuum insulating glazing (VIG). This is appropriate because edge loads in insulating glass units are determined mainly by the enclosed gas volume. VIG used in windows and facades is nevertheless exposed to the same actions and must remain suitable for use throughout the service life of the component (durability). VIG therefore remains a non-regulated and non-harmonised construction product in Europe. CE marking is not possible; instead, evidence of suitability for use is required.
Because thermal and acoustic performance depends directly on maintaining the vacuum and on the durability of the glass coating between the two individual panes, ISO 19916-1:2018-10 should provide means of demonstrating durability. Unlike conventional IGUs, the focus is on loading caused by thermal changes in length and by deformation, because VIG has a very rigid edge-seal system compared with a ‘normal’ IGU. ISO 19916-1 does not take account one-sided climatic load, which may additionally be superimposed by wind pressure and suction loads. Tests at ift Rosenheim produced large deflections and consequently high shear loads in the edge seal. Having in mind knowledge of the actions occurring in window and facade applications, ift Rosenheim has therefore developed a test method that provides a practical demonstration of durability for use in windows and facades.
In the ift test method, the thermal transmittances Ug of the VIG are first determined using a hot plate equipment or a hot box. The units are then installed in a test facade and subjected to climatic and mechanical loading. After the loading cycles, the Ug values are measured again and the deviations from the initial values determined. In addition, small-format vacuum insulating glass units are subjected to combined moisture and UV exposure to test the durability of the edge-seal system under cyclic climatic loading. Finally, another Ug value test is carried out to assess the change in thermal transmittance.
Practical use in windows and facades also requires further performance characteristics, such as sound insulation and solar protection, fire protection and safety in use. Integrating VIG into a window frame or facade construction requires design modifications to existing window or facade systems, particularly to reduce condensation at the glass edge.

ift Rosenheim
References
[1] Christine Milch, Fraunhofer-Institut für Bauphysik IBP, Holzkirchen, Vortragsmanuskript „Sanierung denkmalgeschützter Gebäude - Tradition und Moderne im Einklang” (Dokumentationsband Rosenheimer Fenstertage 2014, ift Rosenheim 10/2014)
[2] Energieeinsparverordnung (EnEV)
[3] Leitfaden zur Planung und Ausführung der Montage von Fenstern und Haustüren (Erstellt vom ift Rosenheim und der RAL-Gütegemeinschaft Fenster und Haustüren e.V., 3/2013)
[4] Fachgerechter Unterhalt und Sanierung von Fenstern, Merkblatt des Kantons Basel-Landschaft Bau- und Umweltschutzdirektion, Kantonale Denkmalpflege
[5] Glaser, Siegfried, Vakuumisolierglas – Eine Alternative zum Dreifachglas? Stand der Entwicklung und der Verfügbarkeit, Vortrag anlässlich der Rosenheimer Fenstertage 2009
[6] Produktionstechniken von Glas, (ProVIG)_IWM/ISE-2012_BMWi
[7] Hochwärmedämmende Fenster- und Fassadensysteme, (HWFF)_ZAE/SKZ_2011_BMWi
[8] Modellierung, Optimierung und technische Integration von Vakuum-Elementen: Sondierung über die Detaillierung von Vakuumgläsern in neuen Holz(Alu)-Fenster-Konstruktionen – Detaillierung, Bau und Simulation, TU Wien/HFA_2017_BMVIT
[9] ISO 19916-1:2018-10, Glass in building – Vacuum insulating glass – Part 1: Basic specification of products and evaluation methods for thermal and sound insulating performance.